Victron Energy Meters are advanced, high-accuracy measurement devices designed for modern solar PV systems, energy storage systems (ESS), and hybrid inverter installations. Installed at the main distribution board, these meters provide real-time insights into power flow, energy consumption, and grid interaction—making them a critical component for efficient energy management.
In Tanzania, where solar energy adoption is growing rapidly across residential homes, commercial buildings, telecom sites, farms, and industrial facilities, Victron Energy Meters deliver the precision and reliability required to optimize energy usage, reduce grid dependence, and protect long-term investments in solar and battery systems.
When integrated with Victron GX devices such as Cerbo GX, Ekrano GX, and the Victron Remote Management (VRM) Portal, these meters enable centralized monitoring, intelligent control, and data-driven decision-making.
Features & Benefits
- High-Precision Energy Measurement : Accurately measures voltage, current, power, and energy flow to ensure reliable system monitoring and control.
- Optimizes Solar & Battery Performance : Enables Victron ESS to minimize grid import/export and maximize self-consumption of solar energy.
- Seamless Victron System Integration : Fully compatible with Cerbo GX, Ekrano GX, and the Victron VRM Portal for real-time local and remote monitoring.
- Real-Time Energy Visibility : Provides instant insight into grid usage, PV production, and AC loads for smarter energy management decisions.
- Supports Single & Three-Phase Systems : ET112 for single-phase up to 100A, ET340 and EM24 for three-phase systems up to 65A per phase.
- Flexible Communication Options : RS485 models for standard installations and Ethernet connectivity on EM24 for network-based systems.
- Improves Energy Cost Control : Helps reduce electricity bills by accurately tracking consumption and controlling grid interaction.
- Essential for ESS Applications : A key component in Victron Energy Storage Systems, enabling intelligent inverter and battery behavior.
- DIN-Rail Compact Design : Space-saving form factor for easy installation inside standard electrical distribution boards.
- Reliable Operation in Harsh Conditions : Designed for long-term performance in residential, commercial, and industrial environments.
- Ideal for Tanzania’s Solar Market : Supports off-grid, hybrid, and grid-tied systems where power stability and efficiency are critical.
- Scalable for Future Expansion : Suitable for small homes today and expandable for larger commercial or industrial systems tomorrow.
Use Cases
- Residential Solar Homes: Monitor energy consumption, optimize solar self-consumption, and minimize electricity bills.
- Commercial Buildings & Offices: Track three-phase power usage, manage loads efficiently, and reduce operational costs.
- Hotels & Hospitality: Ensure stable energy supply, monitor peak loads, and integrate with battery backup systems.
- Telecom Towers & Remote Sites: Accurate load measurement for uninterrupted power systems and efficient battery management.
- Industrial & Small Manufacturing Units: Monitor multi-phase power consumption, prevent overloads, and optimize energy usage.
- Agricultural Operations: Track energy for irrigation systems, cold storage, and processing equipment, maximizing solar energy use.
- Hybrid Mini-Grids: Monitor and control grid import/export, optimize distributed generation, and ensure efficient energy distribution.
- PV Inverter Monitoring: Measure solar inverter output in real-time to analyze system performance.
- Energy Storage Systems (ESS): Enable smart battery control and automate energy flow between PV, load, and grid.
- Remote Energy Management: Use Ethernet or RS485 connectivity with GX devices and VRM Portal for remote monitoring and system diagnostics.
Value Propositions
- Maximize Solar Self-Consumption: Optimize PV and battery use to reduce reliance on the grid.
- Accurate Energy Monitoring: High-precision measurements for power, energy, and load consumption.
- Smart System Control: Enables intelligent energy management via Cerbo GX, Ekrano GX, and VRM Portal.
- Reduce Energy Costs: Real-time monitoring helps identify inefficiencies and lower electricity bills.
- Grid Protection & Stability: Prevents overloading and unwanted energy export/import.
- Flexible Installation: Single-phase and three-phase models suitable for residential, commercial, and industrial setups.
- Future-Ready & Scalable: Compatible with Victron’s ecosystem for expanding energy storage and PV systems.
- Remote Monitoring & Management: Access system data locally or via the internet for proactive maintenance.
- Durable & Reliable: Built with Victron’s proven quality for long-lasting, dependable performance.
Local Market Positioning in Tanzania
- Rising Solar Adoption: Positioned for Tanzania’s growing residential and commercial solar PV market due to increasing energy demand and frequent grid instability.
- Energy Cost Optimization: Helps homeowners and businesses reduce electricity bills by monitoring and controlling energy import/export from the grid.
- Industrial & Commercial Relevance: Suitable for small to medium industries, offices, hotels, and telecom towers needing accurate three-phase energy monitoring.
- Integration with Smart Systems: Compatible with Victron GX devices and VRM Portal, enabling remote monitoring and intelligent energy management in urban and rural areas.
- Reliable Performance: Offers high accuracy and durability suitable for Tanzania’s varying power quality and tropical climate conditions.
- Support for Mini-Grids & Hybrid Systems: Ideal for off-grid or partially grid-connected setups common in rural Tanzania.
- Ease of Installation: Compact DIN-rail design and versatile interfaces (RS485 / Ethernet) make it simple for local electricians and installers to deploy.
- Future-Proof Investment: Enables scalable energy management for residential, commercial, and industrial users as energy infrastructure evolves in Tanzania.
Technical Specification
| Specification | ET112 | ET340 | EM24 |
|---|---|---|---|
| Type | Single-Phase Energy Meter | Three-Phase Energy Meter | Three-Phase Energy Meter |
| Interface | RS485 | RS485 | Ethernet |
| Phases | 1 | 3 | 3 |
| Maximum Current | 100 A | 65 A per phase | 65 A per phase |
| Measurement Type | Direct connection (no CTs required) | Direct connection | Direct connection |
| Accuracy | Class 1 (Active Energy) | Class 1 (Active Energy) | Class 1 (Active Energy) |
| Nominal Voltage | 230 V AC | 230/400 V AC | 230/400 V AC |
| Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
| Display | No display (data via GX/VRM) | No display (data via GX/VRM) | No display (data via GX/VRM) |
| Communication Protocol | Modbus RTU over RS485 | Modbus RTU over RS485 | Modbus TCP over Ethernet |
| Operating Temperature | -40°C to +65°C | -40°C to +65°C | -40°C to +65°C |
| Mounting | DIN-rail | DIN-rail | DIN-rail |
| Ideal Applications | Residential, small commercial | Commercial buildings, small industries | Networked commercial/industrial systems |
| Integration | Victron GX devices, VRM Portal | Victron GX devices, VRM Portal | Victron GX devices, VRM Portal |