The Victron Energy Fuse Holder for Midi-Fuse is a dedicated mounting and connection component designed to house MIDI-type DC fuses in Victron power systems. This holder serves as the critical interface between high-current DC circuits (such as battery feeds, inverters, and charge controllers) and protective fuses built to safeguard wiring and equipment from overload and short-circuit damage.
Features & Benefits
- Designed for MIDI-Type DC Fuses : Specifically engineered to securely hold Victron MIDI fuses, ensuring correct fit and reliable electrical contact in DC power systems.
- Protects Inverters and DC Equipment : Safeguards inverters, batteries, charge controllers, and cabling against over-current and short-circuit faults, helping prevent costly equipment damage.
- High-Current DC Capability : Suitable for 12V, 24V, and 48V DC systems when used with the appropriate MIDI fuse rating, making it ideal for solar and inverter installations.
- Robust and Heat-Resistant Housing : Built with durable materials that withstand high temperatures, dust, and harsh operating conditions commonly found in African environments.
- Secure Bolt-Down Connections : Strong terminal connections reduce voltage drop and minimize the risk of loose wiring, improving system efficiency and long-term reliability.
- Easy and Fast Installation : Simple mounting design allows installers to quickly integrate the fuse holder into new or existing Victron DC systems.
- Compact and Space-Saving Design : Small footprint makes it suitable for tight electrical enclosures, battery compartments, and inverter cabinets.
- Low Maintenance Operation : Once installed, the fuse holder requires minimal upkeep, reducing service time and maintenance costs.
- Fully Compatible with Victron Systems : Seamlessly integrates with Victron inverters, charge controllers, DC distribution components, and battery setups.
- Improves System Safety Compliance : Supports safer electrical installations that align with recommended DC protection practices for solar and backup power systems in Tanzania.
Use Cases
- Used in off-grid solar power systems to protect DC connections between battery banks and Victron inverters or charge controllers from over-current and short-circuit faults.
- Installed in hybrid and backup power systems for homes and small businesses to safely fuse DC supply lines feeding inverters during grid outages.
- Applied in telecom towers and communication shelters to ensure stable and protected DC power distribution for sensitive equipment operating 24/7.
- Integrated into commercial solar installations such as shops, offices, and schools to protect mid-current DC circuits while maintaining system reliability.
- Suitable for mobile and transport power systems, including solar-powered vehicles, boats, and service vans using 12V or 24V DC systems.
- Used by solar installers and electricians as a standard safety component to meet electrical protection requirements and improve system longevity.
- Ideal for renewable energy upgrades or system expansions, allowing safe addition of new DC loads without compromising existing equipment.
Value Propositions
- Ensures reliable DC circuit protection by securely housing MIDI fuses, reducing the risk of equipment damage, fire hazards, and costly downtime in inverter and solar power systems.
- Designed for seamless compatibility with Victron Energy components, making it an ideal choice for professional installers and system integrators using Victron inverters, charge controllers, and batteries.
- Provides long-term durability and stable electrical connections, even in demanding Tanzanian environments with high temperatures, dust, and continuous daily operation.
- Simplifies system maintenance by allowing quick fuse inspection and replacement, minimizing service time for off-grid solar systems, backup power setups, and commercial installations.
- Supports safe and compliant electrical installations, helping installers meet best-practice standards for DC power distribution in residential, commercial, and industrial projects.
- Offers a cost-effective protection solution that extends the lifespan of expensive components such as inverters and battery banks, improving overall system return on investment.
- Well-suited for Tanzania’s growing renewable energy market, including rural electrification, telecom sites, solar mini-grids, and small business power backup systems.
Local Market Positioning in Tanzania
- Well-suited for Tanzania’s fast-growing solar and inverter market, including residential homes, small businesses, and rural electrification projects
- Ideal for off-grid and hybrid power systems, commonly used in areas with unstable or unavailable grid supply
- Supports Victron Energy inverters and charge controllers, a trusted brand among Tanzanian solar installers and EPC contractors
- Helps improve system safety and compliance, reducing risks of DC cable overheating and fire in high-temperature environments
- Practical choice for telecom towers, solar kiosks, lodges, schools, and clinics, where reliable DC protection is essential
- Compact and cost-effective solution for local installers and technicians, allowing easy replacement and maintenance
- Suitable for 12V, 24V, and 48V DC systems, which are widely used in Tanzanian solar installations
- Strong fit for importers, distributors, and solar shops seeking genuine Victron accessories with consistent demand
- Enhances long-term system reliability, lowering maintenance and downtime costs for end users in remote locations
Technical Specification
| Specification | Details |
|---|---|
| Fuse Type Supported | MIDI Fuse |
| Application Type | DC Power Distribution & Protection |
| Nominal System Voltage | 12 V / 24 V / 48 V DC (depending on fuse rating) |
| Maximum Voltage Rating | Up to 58 V DC (fuse dependent) |
| Current Rating | Determined by installed MIDI fuse (typically 30A – 200A) |
| Mounting Type | Surface / Panel Mount |
| Connection Type | Bolt-on terminal connection |
| Terminal Material | Tinned copper |
| Housing Material | High-temperature, impact-resistant plastic |
| Fuse Replacement | Tool-assisted (bolted fuse design) |
| Environmental Protection | Designed for indoor and protected electrical enclosures |
| Operating Temperature Range | Approx. −40 °C to +60 °C |
| Compatibility | Victron MIDI fuses and Victron DC systems |
| Standards Compliance | IEC low-voltage DC protection standards |
| Typical Applications | Inverters, battery banks, solar charge controllers |
| Installation Requirement | Qualified electrician recommended |