OUTPUT |
|
Output Volt Amp Capacity (VA) | 1500 |
Output kVA Capacity (kVA) | 1.5 |
Output Watt Capacity (Watts) | 900 |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Nominal Voltage Details | 230V nominal output in battery mode |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (8) C13 |
Included Output Power Cables | Includes 2 C13 to C14 output power cables. |
Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT |
|
Rated input current (Maximum Load) | 4.4A |
Nominal Input Voltage(s) Supported | 230V AC |
UPS Input Connection Type | C14 inlet |
UPS Input Connection Description | Attached 15cm line cord with C14 inlet. C14 inlet accepts user-supplied AC power cord with country specific plug. |
Input Circuit Breakers | 5.5A |
UPS Input Cord Length (ft.) | 0.5 |
UPS Input Cord Length (m) | 0.2 |
Input Phase | Single-Phase |
BATTERY |
|
Full Load Runtime (min.) | 4.5 min. (900w) |
Half Load Runtime (min.) | 12 min. (450w) |
DC System Voltage (VDC) | 24 |
Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge | See RBC Selector for replacement battery information |
Expandable Runtime | No |
VOLTAGE REGULATION |
|
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 144 to 282 |
Overvoltage Correction | Input voltages between 245 and 282 are reduced by 12% |
Undervoltage Correction | Input voltages between 177 and 199 are boosted by 14% |
Severe Undervoltage Correction | Input voltages between 144 and 176 are boosted by 30% |
USER INTERFACE, ALERTS & CONTROLS |
|
Front Panel LCD Display | Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm | Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert software |
LED Indicators | Front panel LCD display |
SURGE / NOISE SUPPRESSION |
|
UPS AC Suppression Joule Rating | 890 |
UPS AC Suppression Response Time | Instantaneous |
UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set) |
EMI / RFI AC Noise Suppression | Yes |
PHYSICAL |
|
Included Mounting Accessory Description | Pair of mounting ears enable tower and 2-4 post rackmount installation |
Installation Form Factors Supported with Included Accessories | Tower |
Primary Form Factor | Rackmount |
UPS Power Module Dimensions (hwd, cm) | 8.89 x 43.82 x 26.67 |
Rack Height (U Spaces) | 2 |
Minimum Required Rack Depth (cm) | 32.51 |
UPS Power Module Weight (kg) | 13.34 |
Shipping Dimensions (hwd / cm) | 19.81 x 38.10 x 54.10 |
Shipping Weight (kg) | 15.51 |
UPS Housing Material | ABS |
Primary UPS Height (mm) | 889 |
Primary UPS Width (mm) | 4,382 |
Primary UPS Depth (mm) | 2,667 |
ENVIRONMENTAL |
|
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 128 |
Battery Mode BTU / Hr. (Full Load) | 542 |
AC Mode Efficiency Rating (100% Load) | 96% |
COMMUNICATIONS |
|
Communications Interface | USB (HID enabled); DB9 Serial |
Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable | USB and DB9 Serial cabling included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER |
|
Transfer Time | 2-4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 144 |
High Voltage Transfer to Battery Power (Setpoint) | 282 |
SPECIAL FEATURES |
|
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
Green Energy-Saving Features | Greater than 95% efficiency – GREEN UPS |
0
Shopping cart
Tsh 0
- Your cart is empty
- Continue Shopping